Packaging Details : The single row scheme of the micro module data center fully considers the standardized design, energy conservation and capacity expansion compatibility, and uses standardized power, refrigeration and cabinet units to help IT experts seamlessly plan, expand
cabenit quanity : LESS THAN 20
ITcabenit quanity : LESS THAN 20
POWER DENITISY -kW/CAbinet : less than15kW/CABINET
Redundancy style : N/N+1/2N
UPSCAPACITY -kVA : MAX90kVA
UPS : rack-mounted modular
Single Row Scheme Of Micro Module Data Center Energy Saving And Capacity Expansion Compatibility
Advantages and characteristics
VMDC-06-RRS
cabenit: 1*Integrated cabinet+ 1*IT cabenit
UPS: 6kVA rack-mounted
cooling: 5.6kW InRow air-conditioner
Redundancy:N
VMDC-10-RRS
cabenit 1*Integrated cabinet+ 2*ITcabenit
UPS: 10+10(kVA)rack-mounted
cooling: 7.6+7.6kWInRow air-conditioner
Redundancy: N+1
VMDC-20-RRS
cabenit: 1*Integrated cabinet+ 4*ITcabenit
UPS: 20+20(kVA)rack-mounted
cooling: 17.6+17.6kW InRow air-conditioner
Redundancy: N+1
VMDC-30-RRS
cabenit: 1*Integrated cabinet+ 6*ITcabenit
UPS: 30+30(kVA)rack-mounted
cooling: 25.1+25.1kW InRow air-conditione
Redundancy: N+1
VMDC-40-RRS
cabenit: 1*Integrated cabinet+ 9*ITcabenit
UPS: 40+10(kVA)modular
cooling: 21.2*(2+1)kW
Redundancy: N+1
Technical
monitoring system
model | VMDC-06-RRS | VMDC-10-RRS | VMDC-20-RRS | VMDC-30-RRS | VMDC-40-RRS | ODM |
cabenit quanity | 2 | 3 | 5 | 7 | 10 | LESS THAN 20 |
ITcabenit quanity | 2 | 3 | 4 | 6 | 9 | LESS THAN 20 |
POWER DENITISY -kW/CAbinet | 2 | 2 | 4 | 4 | 4 | less than15kW/CABINET |
Redundancy style | N | N+1 | N+1 | N+1 | N+1 | N/N+1/2N |
depth -mm | 1400 | 1400 | 1400 | 1400 | 1400 | customization |
length -mm | 1500 | 2400 | 3600 | 5700 | 6900 | customization |
height -mm | 2000 | 2000 | 2000 | 2000 | 2000 | less than 2500 |
POWER SYSTEM | ||||||
UPSCAPACITY -kVA | 6 | 10+10 | 20+20 | 30+30 | 40+10 | MAX90kVA |
UPS | rack-mounted | rack-mounted | rack-mounted | rack-mounted | modular | rack-mountedmodular |
)battery configuration(1 h) | 12V/40Ah 16Pcs | 12V/65Ah 16Pcs | 12V/65Ah 40Pcs | 12V/100Ah 40Pcs | 12V/150Ah 40Pcs | customization |
PDU | 32A basic 16 port | 32A basic 16 port | 32A basic 16 port | 32A basic 16 port | 32A basic 16 port | customization |
Total input power specification | 63A/1P/220V /50Hz/60Hz | 63A/3P/380V /50Hz/60Hz | 80A/3P/380V /50Hz/60Hz | 125A/3P/380V /50Hz/60Hz | 160A/3P/380V /50Hz/60Hz | customization |
cooling system | ||||||
cooling style | Air cooling | Air cooling | Air cooling | Air cooling | Air cooling | Air cooling, water cooling and chilled water |
air-conditioner configuration-kW | 5.6 | 7.6+7.6 | 17.6+17.6 | 25.1+25.1 | 21.2*(2+1) | Per Situation |
air-conditioner sytle | InRow | InRow | InRow | InRow | InRow | Row / rack / top mounted |
Emergency ventilation | Automatic door opening | Automatic door opening | Automatic door opening | Automatic door opening | Automatic door opening | Automatic door opening |
monitoring sysem | ||||||
monitoring | Touch screen | Touch screen | Touch screen | Touch screen | Touch screen | Optional video, access control, audible and visual / SMS alarm, centralized monitoring, etc |
Temperature and humidity | Temperature and humidity | Temperature and humidity | Temperature and humidity | Temperature and humidity | ||
UPS management | UPS management | UPS management | UPS management | UPS management | ||
air-conditioner management | air-conditioner management | air-conditioner management | air-conditioner management | air-conditioner management | ||
smoke detection | smoke detection | smoke detection | smoke detection | smoke detection | ||
water leakage | water leakage | water leakage | water leakage | water leakage漏水 | ||
Door opening status | Door opening status | Door opening status | Door opening status | Door opening status |
The single row scheme of micro module data center fully considers the standardized design, energy saving and capacity expansion compatibility, and adopts standardized power supply, refrigeration and cabinet units to help it experts seamlessly plan, expand and manage these key infrastructure of data center for the future.
![]() |
Single Row Module Micro Data Center Energy Saving Capacity Expansion Compatibility Images |